EzFloGloE-Z FloGlo is a feed mill product designed for the manufacturer who produces a variety of feeds. E-Z FloGlo has been developed to give feed a golden color, a moist texture, and a sweet aroma. It contains molasses, special fat sources, emulsifiers, and surfactants. E-Z FloGlo is also available with E-Z Guard Preservative for improved mold control.

E-Z FloGlo allows feedmills to run more efficiently by helping to reduce equipment clean up time. Due to its special anti-caking characteristics, it will also help improve customer handling by reducing feed setup in bags and in bulk delivery trucks. E-Z FloGlo will flow in cold weather with minimal insulation/protection of piping.

Physical Properties +

  • Density: Approximately 10.7 – 11.2 lbs/gallon
  • Specific Gravity: 1.30
  • pH: 3.8-4.2
  • Viscosity: At 70oF typical viscosities will average between 1,000 and 8,000 cps, but a range of 500 to 10,000 cps at this temperature is acceptable. Viscosities will typically increase over time and as temperature varies.


Handling Characteristics +

  • Storage Temperature: 40oF to 90oF
  • Product temperature should not exceed 100oF
  • Freeze Flow: 6oF
  • Shelf Life: twelve (12) weeks from date of receipt


Storage and Handling +

Pump and Piping:

  • Positive displacement pump with minimum 2 in. capacity, 3 in. minimum suction line, and 2 in. minimum discharge line. Avoid 90 degree turns.
  • If product temperature is expected to go below 40oF, user should insulate the suction line.
  • If product temperature is expected to drop to 0oF, user should insulate both suction and discharge lines.

Tank:
Preferably a vertical tank with access available and built to handle 1.33 specific gravity product.

The storage tank must be thoroughly cleaned prior to receipt of first load of E-Z FloGlo, and subsequently used for E-Z FloGlo storage only. Adulteration with other products will invalidate any expressed or implied warranties.

Do not store E-Z FloGlo product in mold-contaminated tanks. Storage in a mold-contaminated tank will reduce the effectiveness of the product. If mold problems have been experienced previously, we recommend sending tank samples (both storage and surge tanks) to a laboratory for mold and yeast counts prior to receipt of E-Z FloGlo.

The storage tanks should be equipped to recirculate or mix the product to insure E-Z FloGlo stocks are rotated. Failure to recirculate or mix E-Z FloGlo liquid will result in a portion of the product exceeding the shelf life and handling difficulties will result.

For typical nutrient analysis for E-Z FloGlo, see the product's nutrient profile.